What winter here does to a heat pump
Your furnace, or whatever heats your house now, runs seven months a year here, October through April. That's the season this choice has to hold up in, not just the cold snaps. The overnight low averages 24°F across December, January and February, and it drops to freezing or below on about 145 nights a year, more than half of the nights the heat is running.
A standard heat pump starts losing ground before it even gets to 24°F. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to keep up. Both marks sit above the winter average here, and every single one of those 145 freezing nights falls below both of them. This is not a county where a heat pump deals with cold air a few nights a year. It is dealing with it most of the season.
That doesn't rule a heat pump out. It changes what you're buying. A cold climate model carries a real, tested standard: at 5°F it has to produce at least 1.75 units of heat for every unit of electricity it uses, and hold onto 70 percent of its 47°F capacity at that temperature. Field testing on prototype cold climate units backs this up. Over two winters in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A heat pump built for cold climates is a different machine than the one the $1.89 running cost above assumes, and it's the one worth asking about if you're set on a heat pump here. Only about one night a year here reaches 0°F, well within what these units are built to handle.