Can a heat pump keep up with winter here
Your heat runs nine months a year here, September through May, and the nights get cold through most of that. The overnight low averages 15°F in December, January and February, and it drops to freezing or below on about 165 nights a year, more than half the nights your heat is on. That is the stretch where the two machines stop looking like close substitutes.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. Your average winter low of 15°F is well past both marks, and every single one of those 165 freezing nights falls past both marks too. That is not a cold snap a few times a winter. That is most nights, all winter.
A gas furnace does not have that problem. It burns gas to make heat, and the heat it makes does not depend on how cold it is outside. It puts out the same rated heat on a 15°F night as it does on a 35°F night.
There is a real answer for cold climates: a heat pump built and certified for it. To carry the ENERGY STAR Cold Climate label, a heat pump has to keep making at least 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that temperature, checked by outside testing. In field tests of prototype cold-climate units running through two winters in occupied homes, backup heat only carried a small share of the load between 0°F and 35°F, and the unit running on backup alone was rare even above 0°F. Rio Arriba only sees 0°F on about one night a year, so a cold-climate heat pump is working in its own range here almost every night of the winter. A standard heat pump is not.