What winter here does to a heat pump
Heat runs seven months a year here, October through April, and the overnight low averages 23°F across December, January and February. A standard heat pump starts falling short of its rated output below 40°F and often needs backup heat below about 35°F. Your average winter night is colder than both marks.
About 115 nights a year here drop to freezing or below, over half the nights in the heating season. Every one of those nights is already past both marks. That does not mean the heat pump stops. It means on most winter nights it is working below its rated capacity and calling on backup heat to make up the rest.
The cold here does not run extreme. Fewer than one night a year reaches 0°F. In a field test of cold-climate heat pumps, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. So the backup heat in a heat pump system is filling in on ordinary nights in the 20s and 30s, not fighting off a hard freeze.
A heat pump built to carry the ENERGY STAR Cold Climate label has to make at least 1.75 units of heat per unit of electricity at 5°F, and hold on to at least 70 percent of its warm-weather capacity at that temperature, checked by outside testing. A standard heat pump carries no such guarantee.