Eight months of work
Furnaces here run from October through May, with overnight lows averaging 22°F through December, January and February. That is most of the year spent cycling on, not a few cold snaps.
Takes about a minute. No obligation.
Furnaces here run from October through May, with overnight lows averaging 22°F through December, January and February. That is most of the year spent cycling on, not a few cold snaps.
Winter storms hit San Miguel County 107 times between 2015 and 2024. A furnace that struggles during one of those weeks leaves a house with no backup plan.
San Miguel County logged 421 severe weather events in the last ten years, 107 of them winter storms.
One furnace checkup a year is what gets a house through all of them.




Gas heats more homes in San Miguel County than any other fuel, at 31.1%. Bottled and LP gas heats another 18.6%. That is a lot of furnaces burning fuel, not just moving air with a heating element. A gas furnace needs the burner and igniter working cleanly, the flue venting exhaust out of the house, and the pressure switch and limit controls doing their job. A dirty filter is the easy part to fix. The burner and venting are what a checkup is actually for.
A checkup now catches the burner, the igniter and the venting while there's still time to fix what it finds. Once the lows settle in around 22 degrees, a furnace that's struggling has no good day to quit.
Find a contractorBetween visits, the filter is the one job that's really on the homeowner. A dirty filter chokes airflow, and a furnace starved for air runs hotter than it should and pushes dust straight onto the burner and the flame sensor. Check it monthly during the stretch the furnace runs every day, and swap it when it's gray instead of white. While it's out, look at the vents in each room and make sure none are closed off or blocked by furniture, since a furnace needs somewhere for that air to go. Keep anything stacked near the furnace itself out of the way too, especially anything that burns. Past that, leave the cabinet closed. The burner, the igniter, the heat exchanger, none of that is something to open up between checkups. If the furnace starts making a new noise, short-cycling, or the smell of gas ever shows up, that's not a wait-for-next-year problem.
A furnace left alone collects dust on the burner and dirt on the flame sensor. The flame sensor reads a weak signal and shuts the burner down, sometimes mid-cycle, sometimes on startup. It looks like a dead furnace. Often it's just a sensor that needed wiping clean.
A cracked heat exchanger doesn't announce itself. Neither does a pressure switch going bad or a blower motor wearing down its bearings. These are the things a checkup catches while they're still small. Skip enough years and the furnace is still running, right up until the part that was already failing finally gives out.
A quick tune-up checks the filter, listens to the furnace run, and calls it done. A thorough one pulls the burner cover and looks at the flame itself, because a burner flame should burn steady and blue, not yellow or lifting off the burner. It tests the flue draft to make sure exhaust is actually leaving the house instead of backing up. It checks amp draw on the blower motor, not just whether the blower spins. It inspects the heat exchanger with a light and a mirror, not a glance through an access panel. A fast visit tightens what's loose and wipes what's dusty. A real one tests the limit switch and pressure switch under an actual cycle, because a part can look fine sitting still and still fail under load. If nobody opens the burner compartment, that part of the furnace didn't get checked.
A real tune-up starts before the burner ever lights. The tech pulls the filter and checks the blower wheel for dust buildup, because a choked filter starves the burner of air and shows up later as soot or a yellow flame. The igniter gets a look too, since a hot surface igniter weakens with age and either glows dim or cracks outright. The gas valve and manifold pressure get tested against the furnace's own rating, not a guess. Every electrical connection in the control box gets snugged down, because a loose wire causes the same random shutdown people blame on the thermostat. None of this takes long when nothing's wrong. It takes a lot longer to find once something is.