Cold nights, not extreme ones
Winters here average 18°F overnight through December, January and February. A heat pump works harder below freezing, but that is a normal range for the equipment, not a strain that wears it down early.
Takes about a minute. No obligation.
Winters here average 18°F overnight through December, January and February. A heat pump works harder below freezing, but that is a normal range for the equipment, not a strain that wears it down early.
When a heat pump here is giving you trouble, it is rarely because the climate wore it out. Look at how old the unit is and whether it has been serviced. That is usually where the real answer is.

A heat pump old enough to fail once is old enough to fail again somewhere else.
The real question is whether the unit as a whole is worth sinking more money into, not whether this one repair is worth doing.



Most heat pump failures come down to the reversing valve or the defrost cycle not doing its job. The reversing valve is what switches the unit between heating and cooling, and when it sticks, you get a system stuck blowing cold air when it should be warm, or running nonstop without catching up. The defrost board and sensor are the other common culprit. In cold weather the outdoor coil frosts over, and the unit is supposed to sense that, switch into defrost, clear the ice, then switch back. When that sensor fails or the board behind it goes bad, the coil stays iced over and the whole system loses its ability to move heat at all. A failing capacitor is the other usual suspect, since it's what gets the compressor and fan motors started, and a weak one will make a unit hum, click, or short cycle instead of running clean. None of these are wear from how hard the unit is working. They're parts reaching the end of their life, same as any motor or electrical component does eventually.
A heat pump that fails here usually failed from age, not overuse. That makes a repair a reasonable bet, worth getting looked at rather than written off.
Find a contractor
Watch the outdoor unit first. If the coil is coated in frost or solid ice and the system never clears it on its own, the defrost cycle isn't doing its job. A heat pump that runs constantly without the house reaching temperature is losing the fight somewhere, often the reversing valve or a compressor that's lost capacity. Short cycling, where it kicks on and off in quick bursts, points to a failing capacitor or a control board misreading what the system is doing. Any grinding, clicking, or a hum that doesn't turn into a start is a motor or capacitor telling you it's done. None of these get better by waiting. A system that can't finish its own defrost cycle will keep icing over until it can't move heat at all.
If the reversing valve sticks, the compressor still runs, just fighting the wrong direction or short cycling trying to correct itself. The compressor is not built to run against a stuck valve for days or weeks, and continuing to run it that way is how a stuck valve turns into a failed compressor.
Once the outdoor coil ices over and the defrost cycle is not clearing it, the system cannot pull heat from the outside air anymore. It keeps running anyway, trying to heat the house with a coil that has lost its ability to do that, and the ice only builds from there.
Before anyone comes out, there are a few things worth checking yourself. Go outside and look at the unit. If the outdoor coil is buried in ice or frost that never clears, that's worth noting, but don't chip at it or hose it off. Check the thermostat is set to heat and the temperature is actually set above room temperature, since a setting bumped by accident looks exactly like a broken system. Look at the air filter. A filter clogged with dust chokes off airflow and can make a healthy system act like a failing one. Check your breaker panel for a tripped breaker tied to the heat pump, since a reset is free and takes a minute. Listen for what the unit is actually doing, whether it runs nonstop, cycles on and off quickly, or hums without starting, and hold onto that detail. It tells a technician a lot before they even open the panel.
A diagnostic visit starts with watching the unit run, not taking it apart. A technician will run it in heating mode and see what it actually does. Does it reach temperature, does it short cycle, does the outdoor coil ice over and clear itself on its own. Gauges go on next to check refrigerant pressures, since low pressure points to a leak and high pressure can mean a restriction or a failing compressor. The reversing valve gets tested directly, usually by listening to it shift and checking that the system actually changes modes when asked. The defrost board and sensor get checked too, since a board that won't call for defrost looks the same from inside the house as several other problems. Electrical readings on the capacitor and motors come last, because a motor can look fine sitting still and still be the thing failing under load. Most of this is testing one part at a time until the readings point to the one that's wrong, not guessing from the symptom alone.